X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 296 0.1M Tris-HCl pH8.5, 28% PEG2000, VAPOR DIFFUSION, HANGING DROP, temperature 296K
Unit Cell:
a: 54.269 Å b: 101.383 Å c: 59.586 Å α: 90.00° β: 99.82° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.03 Solvent Content: 39.52
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.8 39.89 57446 2907 97.7 0.220 0.254 15.1
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.8 50 97.7 ? 0.056 ? 4.0 58798 57446 0 0 10.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.8 1.91 89.6 ? 0.212 ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 1.0 ESRF ID29
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
CNS refinement 1.2
MOSFLM data reduction .
SCALEPACK data scaling .