X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 ? AS PER WWPDB ENTRY 2X6A, EXCEPT THE CRYSTAL WAS SOAKED WITH 2MM SMAC (FINAL CONCENTRATION IN THE DROP) FOR 16HRS PRIOR TO DATA COLLECTION., pH 7.5
Unit Cell:
a: 106.518 Å b: 106.518 Å c: 88.854 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 4 21 2
Crystal Properties:
Matthew's Coefficient: 4.25 Solvent Content: 71
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.70 41.983 14682 1356 99.92 0.2208 0.2609 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.70 50.00 99.9 0.08 ? 23.20 7 ? 14682 ? -3.0 64.86
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.70 2.80 100.0 ? 2.30 7.0
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 ? Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement (PHENIX.REFINE)
DENZO data reduction .
SCALEPACK data scaling .
PHASER phasing .