2W2R

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.6 ? SITTING DROPS CONTAINING 100 NL 1.2 MG/ML PROTEIN AND 100 NL OF RESERVOIR SOLUTION (20% V/V ISOPROPANOL, 20% W/V PEG 4000 AND 0.1 M SODIUM CITRATE (PH 5.6)) WERE EQUILIBRATED AGAINST 95 UL RESERVIOURS AT 20.5C. CRYSTALS WERE CRYOPROTECTED BY A QUICK SWEEP THROUGH RESERVOIR SUPPLEMENTED WITH 20% V/V GLYCEROL.
Unit Cell:
a: 86.260 Å b: 86.260 Å c: 70.320 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 4
Crystal Properties:
Matthew's Coefficient: 2.52 Solvent Content: 51.13
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 1.83 33.83 21673 1130 99.8 0.158 0.179 25.26
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.83 35.16 99.8 0.12 ? 10.70 7.3 ? 22813 ? -3.0 21.10
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.83 1.88 99.6 ? 2.00 6.1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 ? ESRF ID23-1
Software
Software Name Purpose Version
REFMAC refinement 5.4.0077
XDS data reduction .
SCALA data scaling .
autoSHARP phasing .