X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 ? HANGING DROP VAPOR DIFFUSION WITH 2 UL (18 MG/ML PROTEIN) AND 2 UL (0.8 M AS, 50 MM TRIS/CL PH 7.5, 200 MM NACL, 5 MM COCL2). CRYSTAL WAS CRYOCOOLED WITH PARAFFIN OIL AS CRYOPROTECTANT. CRYSTAL SIZE WAS 0.6 X 0.6 X 0.2 MM
Unit Cell:
a: 67.014 Å b: 67.014 Å c: 180.806 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 41 2 2
Crystal Properties:
Matthew's Coefficient: 2.2 Solvent Content: 43
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.62 62.87 21642 1143 85.4 0.247 0.297 30.56
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.62 62.00 85.4 0.08 ? 12.80 7.0 ? 21642 ? 0.0 31.00
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.62 1.68 19.0 ? 0.80 1.26
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 ? ? ?
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
d*TREK data reduction .
d*TREK data scaling .
PHASER phasing .