X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.80 ? BATCH METHOD: 6-12 MG/ML MYOGLOBIN, 80-85% OF THE CRYSTALLIZATION STOCK-SOLUTION (3.9 M AMMONIUM SULPHATE, 0.1 M MOPS AND 5-10% OF GLYCEROL PH 6.8)
Unit Cell:
a: 62.872 Å b: 28.762 Å c: 35.347 Å α: 90.00° β: 106.13° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 1.41 Solvent Content: 31.94
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.20 21.95 34337 1825 94.3 0.139 0.168 14.51
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.200 22.000 94.0 0.05000 ? 16.4000 2.700 ? 36225 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.20 1.23 86.6 ? 3.400 2.00
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-3 ? ESRF ID14-3
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
DENZO data reduction .
SCALEPACK data scaling .