X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.50 293 NH4 acetate 150 mM, PEG 3350, Hepes 100 mM, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K, pH 7.50
Unit Cell:
a: 50.470 Å b: 50.470 Å c: 440.406 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 61 2 2
Crystal Properties:
Matthew's Coefficient: 2.20 Solvent Content: 44.08
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.22 30.00 17114 851 95.7 0.203 0.270 34.07
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.220 43.727 96.4 0.08700 0.08700 5.6000 11.700 ? 17253 ? 0.000 42.07
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.22 2.34 98.8 ? 0.34300 2.000 12.20 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-1 ? ESRF ID14-1
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling .
MOLREP phasing .
REFMAC refinement .
PDB_EXTRACT data extraction 3.000