X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 291.0 23% PEG 6000, 0.1M Bis-Tris-Propane, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 291.0K
Unit Cell:
a: 63.736 Å b: 92.913 Å c: 103.693 Å α: 90.00° β: 106.22° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.72 Solvent Content: 54.82
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 2.30 37.01 45931 2000 100.00 0.18478 0.23891 57.743
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.30 50.0 99.8 0.079 0.079 12.0 7.1 51827 51723 0.0 0.0 43.0
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.30 2.35 99.6 ? 0.0302 ? 6.3 3438
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.9807 ESRF ID29
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
ProDC data collection .
DENZO data reduction .
SCALEPACK data scaling .
PHENIX phasing .