X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 298.0 8% PEG 3350, 200 mM Zn Acetate, 5% Glycerol, 0.1 M Imidazole -Malate buffer, pH 8.0, VAPOR DIFFUSION, temperature 298.0K
Unit Cell:
a: 49.869 Å b: 147.492 Å c: 74.315 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 54.14
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.534 47.25 8264 398 91.42 0.23506 0.29287 36.253
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.53 47.25 92.6 0.159 0.159 7.5 3.1 8675 8675 0.0 0.0 36
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.53 2.59 100 ? 0.614 1.9 3.1 924
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 105.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 1.5418 ? ?
Software
Software Name Purpose Version
CrystalClear data collection .
MOLREP phasing .
REFMAC refinement 5.2
DENZO data reduction .
SCALEPACK data scaling .