X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.2 293.0 10-15% (w/v) PEG 4000, 0.05M sodium citrate, 0.2M potassium phosphate, 0.08M bis-tris, 0.12M KCl, 0.003M dithiothreitol, 0.02M tris (2-carboxyethyl) phosphine hydrochloride, 0.0026M 1,2-dihexanoyl phosphatidylinositol 4,5-biphosphate, 0.016M nonylglucoside , pH 6.2, VAPOR DIFFUSION, SITTING DROP, temperature 293.0K
Unit Cell:
a: 98.416 Å b: 98.416 Å c: 92.624 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 4
Crystal Properties:
Matthew's Coefficient: 3.10 Solvent Content: 60.30
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.2 29.5 43987 2179 97.9 0.232 0.256 51.229
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.2 100 97.9 ? 0.054 17.0 3.7 43991 43991 0 -3 46.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.20 2.28 99.7 ? 0.309 3.9 3.7 4450
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X29A 1.1000 NSLS X29A
Software
Software Name Purpose Version
CNS refinement .
PDB_EXTRACT data extraction 2.000
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback