X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 298 25% PEG 3350, 0.1M HEPES pH 7.4, 10 mM MnCl2, 10 mM GDP, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 63.506 Å b: 119.112 Å c: 86.710 Å α: 90.00° β: 107.35° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.25 Solvent Content: 45.23
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.65 33.33 135193 7148 96.45 0.20597 0.23762 19.121
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.650 50.000 96.600 0.082 ? 9.000 6.900 ? 142474 2 2 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.65 1.71 80.30 ? ? ? 5.90 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 14-BM-C 0.9 APS 14-BM-C
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
REFMAC refinement .
PDB_EXTRACT data extraction 2.000
HKL-2000 data reduction .
HKL-2000 data scaling .
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback