X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 277.0 20% PEG 6000, 0.1M magnesium chloride, 0.1M Tris-HCl, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 277.0K
Unit Cell:
a: 69.103 Å b: 91.850 Å c: 63.186 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.82 Solvent Content: 56.34
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MAD THROUGHOUT 1.40 27.61 72486 7338 91.4 ? 0.203 21.5
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.4 27.6 97.9 ? 0.051 26.6 4.6 77901 77901 ? -3 16.3
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.4 1.45 97.7 ? 0.392 4.3 4.6 7639
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 93 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-ID 0.9789, 0.9791, 0.9641 APS 19-ID
Software
Software Name Purpose Version
SBC-Collect data collection .
SOLVE phasing .
CNS refinement 1.1
HKL-2000 data reduction .
HKL-2000 data scaling .