X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 277 CaCl2, PEG , pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 85.567 Å b: 50.359 Å c: 161.621 Å α: 90.000° β: 98.720° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.61 Solvent Content: 52.91
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.270 48.030 16224 1114 75.300 ? 0.314 102.200
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.25 50 79.6 ? 0.085 7.2 3.5 16888 16888 ? -3 66
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.25 3.37 64.7 ? 0.451 1.5 2.5 1371
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON CHESS BEAMLINE A1 0.98 CHESS A1
Software
Software Name Purpose Version
CNS refinement 1.1
PDB_EXTRACT data extraction 2.000
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
AMoRE phasing .