X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 295 20% PEG4000, 10% Glycerol, 0.2M MgSO4, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 295K
Unit Cell:
a: 66.397 Å b: 88.951 Å c: 95.107 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.34 Solvent Content: 47.44
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.25 40.29 26697 2652 97.4 0.207 0.213 37.7
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.25 50 96.2 0.055 ? 33.3 ? ? 27842 0.0 ? 18.0
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.25 2.33 80.8 ? ? 4.7 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PAL/PLS BEAMLINE 4A 1.00000 PAL/PLS 4A
Software
Software Name Purpose Version
CNS refinement 1.1
HKL-2000 data collection .
HKL-2000 data reduction .
SCALEPACK data scaling .
CNS phasing .