X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.5 277 34% pentaerythritol propoxylate, 0.1M sodium citrate, pH 5.5, 0.2M potassium chloride, VAPOR DIFFUSION, SITTING DROP, temperature 277K
Unit Cell:
a: 97.846 Å b: 142.465 Å c: 150.268 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 4.07 Solvent Content: 69.77
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MAD THROUGHOUT 2.400 28.00 81106 8214 98.900 ? 0.2597 51.093
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.40 30 99.5 ? 0.061 16.1 14.5 82485 82020 ? ? 31.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.40 2.49 99.2 ? 0.27 ? 14.1 11759
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL9-2 0.97925, 0.89194, 0.97927 SSRL BL9-2
Software
Software Name Purpose Version
CNS refinement .
PDB_EXTRACT data extraction 2.000
HKL-2000 data collection .
DENZO data reduction .
SCALEPACK data scaling .
SHARP phasing .