SOLUTION NMR


NMR Experiment
Experiment Type Sample Contents Ionic Strength Solvent pH Pressure Temprature (K)
1 2D 1H-15N HSQC 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
2 2D 1H-13C HSQC aliphatic 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
3 3D HNHA 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
4 3D HNCACB 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
5 3D CBCA(CO)NH 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
6 3D 1H-15N NOESY 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
7 3D 1H-13C NOESY aliphatic 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
8 3D 1H-13C NOESY aromatic 1 mM [U-98% 13C; U-98% 15N] rNedd4 WW2, 1.8 mM potassium phosphate, 1 mM DTT, 137 mM sodium chloride, 2.7 mM potassium chloride, 10 mM sodium phosphate, 90% H2O/10% D2O 156 90% H2O/10% D2O 7.5 ambient 25
NMR Spectrometer Information
Spectrometer Manufacturer Model Field Strength
1 Varian INOVA 600
NMR Refinement
Method Details Software
DGSA-distance geometry simulated annealing ? 1
NMR Ensemble Information
Conformer Selection Criteria structures with the lowest energy
Conformers Calculated Total Number 20
Conformers Submitted Total Number 9
Representative Model 1 (lowest energy)
Computation: NMR Software
# Classification Version Software Name Author
1 refinement 1.1 ARIA Dr. Michael Nilges, Institut Pasteur
2 geometry optimization 1.1 ARIA Dr. Michael Nilges, Institut Pasteur
3 structure solution 1.1 ARIA Dr. Michael Nilges, Institut Pasteur
4 processing ? NMRPipe Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax
5 chemical shift assignment ? NMRView Johnson, One Moon Scientific
6 peak picking ? NMRView Johnson, One Moon Scientific
7 data analysis ? NMRView Johnson, One Moon Scientific
8 processing ? NMRDraw Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax
Feedback Form
Name
Email
Institute
Feedback