X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? ? 12% PEG 6000, 200 MM TRIS PH 8.0
Unit Cell:
a: 76.719 Å b: 82.746 Å c: 118.079 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.44 Solvent Content: 49.7
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.54 23.93 105364 2677 97.1 0.163 0.188 12.31
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.54 25.00 97.1 0.06 ? 19.30 3.6 ? 108114 ? -3.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.54 1.60 81.6 ? 2.60 3.0
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM14 ? ESRF BM14
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .