X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 ? 20% POLYETHYLENE GLYCOL 8000 0.2M MGCL2 0.1M TRIS, PH 8.5
Unit Cell:
a: 115.760 Å b: 115.760 Å c: 61.790 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 65 2 2
Crystal Properties:
Matthew's Coefficient: 3.6 Solvent Content: 66
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.82 6.00 5155 566 93.2 0.229 0.276 60.3
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.80 50.00 99.3 0.07 ? 20.00 9 ? 6181 ? 2.0 61.9
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.80 2.90 100.0 ? 3.00 9
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 32-ID ? APS 32-ID
Software
Software Name Purpose Version
CNS refinement 1.1
DENZO data reduction .
SCALEPACK data scaling .
CNS phasing .