2I5M

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293.15 reservoir solution: 1.5 M lithium sulfate, 0.1 M TRIS pH 7.5, 15% glycerol for cryoprotection. protein solution: 20 mM TRIS pH 7.5, 50 mM NaCl, 3 mM MgCl2, 17.4 mg/ml protein. crystallization setup: 0.8 microliter protein solution:0.8 microliter reservoir solution, VAPOR DIFFUSION, SITTING DROP, temperature 293.15K
Unit Cell:
a: 58.627 Å b: 58.627 Å c: 46.798 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 3.09 Solvent Content: 60.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.300 19.190 4231 214 98.624 0.205 0.227 33.462
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.220 20 98.319 0.049 ? 26.650 6.7 4700 4621 ? 0 41.593
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.22 2.30 83.30 ? ? 7.9 5.4 390
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON BESSY BEAMLINE 14.2 0.9537 BESSY 14.2
Software
Software Name Purpose Version
XSCALE data scaling .
AMoRE phasing .
REFMAC refinement .
PDB_EXTRACT data extraction 2.000
MAR345 data collection v. 0.9.31
XDS data reduction VERSION June 2005