2HB8

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 277 Ammonium sulphate 1.4M, Mes 0.1M, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 44.990 Å b: 51.560 Å c: 132.210 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.66 Solvent Content: 53.72
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.0 20.0 20882 900 ? 0.188 0.224 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 20 99.3 0.053 ? 21.3 3.6 20882 20882 1.0 1.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.0 2.07 97.9 ? ? 9.4 3.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.933 ESRF ID14-2
Software
Software Name Purpose Version
ADSC data collection .
HKL-2000 data reduction .
CNS refinement .
HKL-2000 data scaling .
CNS phasing .