X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.6 289 25 - 30 % PEG 4,000, 0.1 M Sodium Citrate pH 5.4 - 5.8, 0.2M Ammonium Acetate, pH 5.6, VAPOR DIFFUSION, SITTING DROP, temperature 289K
Unit Cell:
a: 46.874 Å b: 59.596 Å c: 109.771 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.46 Solvent Content: 49.98
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.400 40 12578 642 99.920 0.207 0.248 13.318
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.4 40 100 ? 0.136 13.5 6.9 12619 12619 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.4 2.53 100 ? 0.35 5.4 7.2 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.97950 ESRF ID29
Software
Software Name Purpose Version
SCALA data scaling .
MOLREP phasing .
REFMAC refinement .
PDB_EXTRACT data extraction 2.000
ProDC data collection .
MOSFLM data reduction .
CCP4 data reduction (SCALA)
CCP4 data scaling (SCALA)