X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.7 293 20% PEG 4000, 0.240 M CaCl2, 5% glycerol, pH 8.7, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 70.050 Å b: 91.690 Å c: 133.700 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.41 Solvent Content: 49.01
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? ? 2.300 50.000 36590 1819 93.800 0.225 0.26 33.885
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.30 50.0 99.2 0.086 ? ? ? 38285 38285 -3 -3 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.30 2.38 97.9 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 200 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-ID 0.979 APS 19-ID
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
CNS refinement 1.1
PDB_EXTRACT data extraction 1.701
HKL-2000 data reduction .