X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.0 291 15 mg/ml elastase, 25 mM Sodium Acetate, 135 mM Sodium sulfate, 10 ul drop (5x5). See also: Sawyer et al., J.Mol.Biol. 118, 137-208 (1978). , pH 5.0, VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 52.540 Å b: 58.010 Å c: 75.660 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.22 Solvent Content: 44.67
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.000 500.000 11177 650 37.100 ? 0.234 22.571
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 500.0 37.1 ? ? ? ? ? 11177 ? 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 277 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE ELLIOTT GX-6 1.5418 ? ?
Software
Software Name Purpose Version
XDS data reduction .
CNS refinement .
XDS data scaling .
CNS phasing .