X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 3.5 293 25% w/v PEG1500, 0.1M citric acid, pH 3.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 44.768 Å b: 59.417 Å c: 66.896 Å α: 90.00° β: 98.42° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.65 Solvent Content: 53.67
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.91 44.29 23335 1612 85.5 0.207 0.239 25.80
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 50.00 90.400 0.121 ? ? ? ? 24731 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.97 56.100 ? ? ? ? 1526
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ALS BEAMLINE 8.2.1 1.0 ALS 8.2.1
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
PHASER phasing .
CNS refinement 1.1
PDB_EXTRACT data extraction 1.701
HKL-2000 data reduction .
Feedback Form
Name
Email
Institute
Feedback