X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.80 ? 50 MM NAOAC, 15% PEG 2000 MME, 10% GLYCEROL, 4% MPD, pH 6.80
Unit Cell:
a: 71.340 Å b: 71.340 Å c: 587.990 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 41 21 2
Crystal Properties:
Matthew's Coefficient: 3.4 Solvent Content: 63
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.80 14.95 36066 1119 92.5 0.252 0.308 67.2
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.800 30.000 92.5 0.01000 ? 17.1000 5.700 ? 36358 ? 2.000 62.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.80 3.01 75.6 ? 3.600 3.65
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON BESSY BEAMLINE 14.2 ? BESSY 14.2
Software
Software Name Purpose Version
CNS refinement 1.1
XDS data reduction .
XSCALE data scaling .
MOLREP phasing .