X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 291 PEG 6000, MES, DMSO, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 52.061 Å b: 95.704 Å c: 67.587 Å α: 90.00° β: 102.88° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.5 Solvent Content: 49.5
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.3 50 27091 1320 ? 0.216 0.23 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.3 50 98.0 ? ? ? ? 28372 28372 1 1 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.3 2.34 96.0 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 1.5418 ? ?
Software
Software Name Purpose Version
HKL-2000 data collection .
SCALEPACK data scaling .
CNS refinement .
HKL-2000 data reduction .
CNS phasing .