X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.6 292 10 % PEG 6000, 0.1 M sodium citrate, 0.5 M lithium sulfate, 4 microlitre protein, 4 microlitre precipitant, 1 microlitre 50 mM TMP, pH 4.6, VAPOR DIFFUSION, SITTING DROP, temperature 292K
Unit Cell:
a: 71.494 Å b: 73.064 Å c: 134.738 Å α: 89.93° β: 80.92° γ: 81.11°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.54 Solvent Content: 54.9
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION Phase extension in DM THROUGHOUT 1.66 73. 281394 14902 94.3 0.1450000 0.1960000 14.14
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.66 32.12 94.2 0.0530000 0.0520000 10.9 3.8 297160 1141819 0.0 0.0 19.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.66 1.74 81.2 ? 0.3320000 2.00 2.0 75372
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM14 ? ESRF BM14
Software
Software Name Purpose Version
SOLVE phasing .
REFMAC refinement .
MOSFLM data reduction .
CCP4 data scaling (SCALA)
Feedback Form
Name
Email
Institute
Feedback