X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 292.15 Tris/HCl, PEG 3500, lithium sulfate, strontium chloride, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 292.15K
Unit Cell:
a: 51.433 Å b: 184.837 Å c: 172.026 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.66 Solvent Content: 54
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.4 8.0 144550 7227 ? 0.197 0.212 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.4 8.0 96.3 ? 0.075 18.2 2.82 ? 144550 0.0 0.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.40 1.42 97.5 ? 0.141 4.9 2.85 7312
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MPG/DESY, HAMBURG BEAMLINE BW6 1.54 MPG/DESY, HAMBURG BW6
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
CNS refinement .
CNS phasing .
Feedback Form
Name
Email
Institute
Feedback