X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 291 MPD, MES, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K
Unit Cell:
a: 114.676 Å b: 114.676 Å c: 52.570 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 4
Crystal Properties:
Matthew's Coefficient: 2.4 Solvent Content: 48.2
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.80 29.85 60333 3224 100.00 0.17758 0.23778 25.971
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.80 30.00 99.8 0.084 ? 17.1 4.0 63577 63577 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.80 1.86 99.8 ? ? 1.6 3.8 6280
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SRS BEAMLINE PX9.6 0.87000 SRS PX9.6
Software
Software Name Purpose Version
REFMAC refinement 5.2.0005
HKL-2000 data reduction .
SCALEPACK data scaling .
MOLREP phasing .
Feedback Form