1X13

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.6 293 ammonium acetate, trisodium citrate dihydrate, PEG 4000, pH 5.6, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 38.763 Å b: 66.902 Å c: 76.300 Å α: 67.11° β: 80.66° γ: 81.23°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.1 Solvent Content: 40.3
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.90 30.0 48914 2587 ? 0.18135 0.22445 27.620
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 30.0 93.8 ? ? ? ? 53895 48914 3.0 3.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.97 93.8 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.933 ESRF ID14-2
Software
Software Name Purpose Version
REFMAC refinement 5.1.24
DENZO data reduction .
SCALEPACK data scaling .
MOLREP phasing .