X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.00 279 25% PEG 8000, 0.1M MES PH6.0, TEMPERATURE 279 KELVIN, pH 6.00
Unit Cell:
a: 57.300 Å b: 61.200 Å c: 72.000 Å α: 82.80° β: 73.70° γ: 87.30°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.03 Solvent Content: 39
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.25 27.52 227130 2141 88.94 0.1400 0.1530 8.521
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.150 30.000 84.8 0.08200 ? 3.6000 2.300 ? 280898 ? ? 6.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.15 1.19 70.0 ? 1.300 1.30
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 ? ESRF ID14-2
Software
Software Name Purpose Version
REFMAC refinement .
DENZO data reduction .
SCALA data scaling .
AMoRE phasing .
Feedback Form
Name
Email
Institute
Feedback