X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 277 PEG 8000, ammonium acetate, MOPSO-Na+, DTT, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 57.221 Å b: 361.291 Å c: 57.317 Å α: 90.00° β: 98.39° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.28 Solvent Content: 45.61
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.11 54.10 103258 5163 78.7 0.225 0.289 34.9
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.11 54.10 78.7 ? ? ? ? 103325 103258 0.0 0.0 23.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.10 2.23 38.1 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.933 ESRF ID14-2
Software
Software Name Purpose Version
CNS refinement 1.0
ProDC data collection .
PROW data scaling .
AMoRE phasing .
Feedback Form