X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.50 303 triethanolamine, MgCl2, dithionite, PEG 4000, Hepes, MPD, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 303K, pH 7.50
Unit Cell:
a: 113.015 Å b: 151.845 Å c: 174.866 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.80 Solvent Content: 56.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.60 19.91 338357 16885 86.0 0.152 0.173 18.80
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.600 40.000 86.4 ? 0.06 17.5000 2.630 ? 338532 ? 0.000 15.50
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.60 1.72 0.5 ? 0.184 3.900 1.80 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-4 ? ESRF ID14-4
Software
Software Name Purpose Version
CNS refinement 1.1
DENZO data reduction .
SCALEPACK data scaling .
EPMR phasing .