X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.7 290 PEG 8000, ISOPROPANOL, pH 6.7, VAPOR DIFFUSION, HANGING DROP, temperature 290K
Unit Cell:
a: 93.430 Å b: 72.100 Å c: 60.880 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.30 Solvent Content: 46.42
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.00 46.52 27360 2733 96.0 0.17 0.216 12.9
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 46.6 96.7 ? 0.124 5.7 3.0 27556 27556 0 0 12.01
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.00 2.11 96.7 ? 0.476 1.6 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE ENRAF-NONIUS 1.5418 ? ?
Software
Software Name Purpose Version
CNS refinement 1.0
DENZO data reduction .
CCP4 data scaling (SCALA)
AMoRE phasing .