1OQB

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4 293 8-12% Peg8000, 50mM Potassium Dihydrogen Phosphate and 20% Glycerol as cryoprotectant, pH 4, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 81.908 Å b: 145.791 Å c: 192.424 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.44 Solvent Content: 49.10
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.80 20.00 44537 935 79.32 0.22477 0.24803 27.124
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.8 20 79.3 ? 0.058 12.1 ? 57328 45472 -3.0 -3.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.8 2.85 32.0 ? 0.252 ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MAX II BEAMLINE I711 0.8423 MAX II I711
Software
Software Name Purpose Version
REFMAC refinement 5.1.24
DENZO data reduction .
SCALEPACK data scaling .
AMoRE phasing .