X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.00 301 PEG 8,000 25%, NACL 100 MM, SODIUM ACETATE 50 MM, PH 4, T=28C
Unit Cell:
a: 86.100 Å b: 86.100 Å c: 97.800 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: H 3 2
Crystal Properties:
Matthew's Coefficient: 3.40 Solvent Content: 64
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION OTHER THROUGHOUT 1.50 30.0 22503 2275 97.8 0.159 0.194 23
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.500 30.000 99.7 0.05800 ? 33.0000 9.000 ? 22503 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.50 1.53 97.0 ? 6.000 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 ? ESRF ID14-2
Software
Software Name Purpose Version
REFMAC refinement .
DENZO data reduction .
SCALEPACK data scaling .
CCP4 phasing .
Feedback Form