1NKN

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.9 289 sodium chloride, sodium azide, MOPS, PEG 200 MME, pH 6.9, VAPOR DIFFUSION, HANGING DROP, temperature 289K
Unit Cell:
a: 54.034 Å b: 73.303 Å c: 102.975 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.83 Solvent Content: 56.14
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.50 40.00 12880 911 87.4 0.2467 0.2893 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.50 40.00 90.4 0.062 ? 21.1 4.7 14762 13342 2.0 2.0 49.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.50 2.59 75.7 ? ? 5.28 2.76 1458
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON CHESS BEAMLINE A1 0.939 CHESS A1
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
AMoRE phasing .
CNS refinement 1.0