X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 277 PEG6000, SODIUM CHLORIDE, TRIS-HCL, EDTA, HEPES, DTT, pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 96.109 Å b: 116.972 Å c: 60.562 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.38 Solvent Content: 48.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.10 19.87 38133 1899 93.9 ? 0.224 14.5
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.1 20 99.8 ? 0.102 ? ? 40291 40291 0 0 3.6
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.10 2.17 100 ? 0.301 ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 120 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-4 0.934 ESRF ID14-4
Software
Software Name Purpose Version
ProDC data collection .
SCALEPACK data scaling .
CNS refinement .
CNS phasing .