X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 298 0.1M Mes pH 6.5, 12% PEG 20,000, VAPOR DIFFUSION, SITTING DROP, temperature 298K
Unit Cell:
a: 144.3 Å b: 81.800 Å c: 125.400 Å α: 90.00° β: 111.70° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.719 Solvent Content: 54
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.8 19.91 32867 1616 98.2 ? 0.275 31.9
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.8 20.00 99.4 0.103 ? 14.8 3.0 33394 33394 ? ? 30.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.80 2.85 93.2 ? ? 3.9 2.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 111 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL7-1 1.08 SSRL BL7-1
Software
Software Name Purpose Version
AMoRE phasing .
CNS refinement .
DENZO data reduction .
SCALEPACK data scaling .