X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.5 ? THE PROTEIN SOLUTIONS CONTAINED 10MM CA2+, 0.1M NACL, 5% PEG 4K IN 0.01M CHESS BUFFER (PH 9.5) AND AN ENZYME CONCENTRATION OF 11MG/ML; THE SOLUTION IN RESERVOIR CONTAINED 10% PEG 4K IN SAME BUFFER, ROOM TEMPERATURE OF 17 DEGREES C.
Unit Cell:
a: 97.130 Å b: 103.690 Å c: 23.270 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.09 Solvent Content: 37.
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION STRUCTURE REFINEMENT FULL REFINEMENT CONSISTING OF INITIAL MINIMIZATION, SLOW COOLING-SA 3000K, POSITIONAL AND B-FACTOR REFINEMENT. 2.13 6.0 10174 1063 77.8 0.152 0.255 25.41
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.13 40. 86.1 0.0459 ? 31.2 2.5 ? 12001 ? 0. 26.24
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.13 2.23 46.28 ? 4.9 1.6
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 280 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU RUH2R ? ? ?
Software
Software Name Purpose Version
XENGEN data collection .
XENGEN data reduction .
X-PLOR model building .
X-PLOR refinement .
XENGEN data scaling .
X-PLOR phasing .