SOLUTION NMR


NMR Experiment
Experiment Type Sample Contents Ionic Strength Solvent pH Pressure Temprature (K)
1 2D TOCSY SPECIFIC 13C LABELLING OF GLYCINE 15,44,48,61,79,83 ? ? 4.50 ? 298.00
2 2D NOESY SPECIFIC 13C LABELLING OF GLYCINE 15,44,48,61,79,83 ? ? 4.50 ? 298.00
3 3D_ 13C-SEPARATED_NOESY SPECIFIC 13C LABELLING OF GLYCINE 15,44,48,61,79,83 ? ? 4.50 ? 298.00
NMR Spectrometer Information
Spectrometer Manufacturer Model Field Strength
1 Bruker DRX 500
NMR Refinement
Method Details Software
SIMULATED ANNEALING, RANDOM LOOP RESEARCH VALIDATED WITH NOE BACK-CALCULATION ENERGY MINIMIZATION AND MOLECULAR DYNAMIC THE STRUCTURES ARE BASED ON A TOTAL OF 915 RESTRAINTS AND 272 ARE LONG-RANGE NOES. 1
NMR Ensemble Information
Conformer Selection Criteria BACK CALCULATED DATA AGREE WITH EXPERIMEN TAL NOESY SPECTRUM, STRUCTURES WITH ACCEPTABLE COVALENT GEOMETRY,STRUCTURES WITH FAVORABLE NON-BOND ENERGY,STRUCTURES WITH THE LEAST RESTRAINT VIOLATIONS,STRUCTURES WITH THE LOWEST ENERGY, TARGET FUNCTION
Conformers Calculated Total Number 100
Conformers Submitted Total Number 11
Representative Model ()
Computation: NMR Software
# Classification Version Software Name Author
1 refinement 97 DISCOVER 95, MSI
2 structure solution 95 Felix ?
3 structure solution 98 97 AND ?
4 structure solution 97 NMR_REFINE ?
5 structure solution 95 HOMOLOGY ?
6 structure solution ? 97 ?
7 structure solution ? 98 ?