X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.50 ? 40-50% PEG-MME 550, 10MM ZNSO4, 0.1M MES PH 6.5
Unit Cell:
a: 79.636 Å b: 79.636 Å c: 99.867 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 63
Crystal Properties:
Matthew's Coefficient: 2.53 Solvent Content: 51.02
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.90 68.97 26810 1410 100 0.165 0.207 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.900 20.000 100.0 0.08400 ? 12.9000 5.300 ? 35114 ? 2.000 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.97 100.0 ? 4.300 3.50
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SRS BEAMLINE PX9.6 ? SRS PX9.6
Software
Software Name Purpose Version
REFMAC refinement .
MOSFLM data reduction .
SCALEPACK data scaling .
AMoRE phasing .