X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 310 PEG 3350, HEPES, MPD , pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 310K
Unit Cell:
a: 60.12 Å b: 166.14 Å c: 79.53 Å α: 90° β: 90° γ: 90°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 53.81
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? THROUGHOUT 2.23 5.0 30946 3085 86.1 ? 0.271 25.5
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.23 50 99 0.106 ? 8.1 3.3 ? 36815 ? 0.00 9.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.23 2.41 94 ? ? ? 2.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 120 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE SIEMENS ? ? ?
Software
Software Name Purpose Version
CNS refinement .
X-GEN data reduction .
X-GEN data scaling .
CNS phasing .