X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 294 0.1M MES pH6.5, 10% w/v polyethylene glycol 20000, 3% w/v 1,6-hexandiol, VAPOR DIFFUSION, HANGING DROP, temperature 294K
Unit Cell:
a: 125.774 Å b: 53.167 Å c: 54.262 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.55 Solvent Content: 51.70
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? ? 1.6 25. 47560 2378 96.6 0.1930000 0.2510000 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.6 25 96.6 0.0430000 ? 16.4 9.4 49560 47875 0 0 20.694
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.6 1.66 86. ? ? ? 4.3 4227
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100. K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X4A ? NSLS X4A
Software
Software Name Purpose Version
SHARP phasing .
REFMAC refinement .
DENZO data reduction .
SCALEPACK data scaling .