SOLUTION NMR


NMR Experiment
Experiment Type Sample Contents Ionic Strength Solvent pH Pressure Temprature (K)
1 3D HNCA 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
2 3D 15N EDITED NOESY 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
3 2D 15N HSQC 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
4 2D 13C HMQC 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
5 3D CBCA(CO)NH 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
6 3D HBHA(CO)NH 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
7 3D HNCACB 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
8 3D HNCO 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
9 2D 13C 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
10 15N FILTERED NOESY 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
11 2D 13C FILTERED NOESY 0.5 MM COLLAGENASE-3 15N, 13C, 20 MM TRIS D11, 20 MM CACL2, 0.02% NAN3, 5 MM DTT, 100 MM NACL, 0.1 MM ZNCL, 100 mM NACL ? 6.80 AMBIENT 310.00
NMR Spectrometer Information
Spectrometer Manufacturer Model Field Strength
NMR Refinement
Method Details Software
SIMULATED ANNEALING AND ENERGY MINIMIZATION ? 1
NMR Ensemble Information
Conformer Selection Criteria BACK CALCULATED DATA AGREE WITH EXPERIMENTAL NOESY SPECTRUM, STRUCTURES WITH ACCEPTABLE COVALENT GEOMETRY,STRUCTURES WITH FAVORABLE NON-BOND ENERGY,TARGET FUNCTION
Conformers Calculated Total Number 50
Conformers Submitted Total Number 20
Representative Model 1 (?)
Computation: NMR Software
# Classification Version Software Name Author
1 refinement 98.1 X-PLOR BRUNGER
2 structure solution 97 Felix ?
3 structure solution 2.5 NMRCompass ?
4 structure solution 98 Insight II ?
5 structure solution 97 QUANTA ?