X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.7 291 A SOLUTION CONTAINING 40 MG/ML OF LYSOZYME (SIGMA L-6876, BATCH NUMBER, LOT 65H7025, IE A DIFFERENT SIGMA SAMPLE TO THE EXPERIMENTS DESCRIBED ABOVE) IN 10 MM SODIUM CITRATE BUFFER PH 4.7 WAS MIXED IN AN EPPENDORF TUBE WITH EQUAL VOLUMES OF 12 % SODIUM CHLORIDE (BDH). THE MIXTURE WAS FILTERED THROUGH A 0.22 UM FILTER AND 8 UL DROPS WERE MANUALLY DISPENSED UNDER PARAFFIN OIL USING A GILSON MICRO PIPPETTE. OVER 20 IDENTICAL DROPS WERE SET UP AND, WITHIN A WEEK, SINGLE CRYSTALS TYPICALLY MEASURING 0.5 X 0.4 X 0.3 MM WERE OBTAINED IN MOST OF THE DROPS. CRYSTALLISATION TOOK PLACE AT A TEMPERATURE OF 18 - 20 C., drops under paraffin oil, temperature 291K
Unit Cell:
a: 79.230 Å b: 79.230 Å c: 37.940 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.08 Solvent Content: 40.78
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.80 20.00 10979 ? 94.1 0.171 0.206 22.9
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 99 85.5 0.077 0.08 22.6 6.1 ? 12081 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 293 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU RU200 ? ? ?
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
X-PLOR refinement 3.1