ELECTRON MICROSCOPY


Sample

13 protofilament paclitaxel stabilised GDP microtubule

Specimen Preperation
Sample Aggregation State FILAMENT
Vitrification Instrument ?
Cryogen Name ETHANE
Sample Vitrification Details Paclitaxel stabilized GDP microtubules were applied to a glow discharged grid, incubated for 30 seconds at room temperature following which excess sample was wicked off. This step was repeated again. Purified P. falciparum kinesin 8B-motor domain was immediately added to the grid, and excess sample was drawn out by pipetting. Kinesin was added again and the grid was transferred to a pre-equilibrated Vitrobot. Excess liquid was blotted off, and the grid was plunge frozen in liquid ethane.
3D Reconstruction
Reconstruction Method HELICAL
Number of Particles 30442
Reported Resolution (Å) 3.2
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type HELICAL
Map-Model Fitting and Refinement
ID 1
Refinement Space ?
Refinement Protocol ?
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å2) 50.75
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model TFS KRIOS
Minimum Defocus (nm) 600
Maximum Defocus (nm) 2400
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS ?
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 81000
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION RELION 3.1
IMAGE ACQUISITION EPU ?
CTF CORRECTION CTFFIND 4.1
MODEL FITTING Coot 0.9.8.1
MODEL FITTING ISOLDE 1.0b3
RECONSTRUCTION RELION 3.1
MODEL REFINEMENT PHENIX 1.20.1
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION ?
Feedback Form