X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 295 50 mM MOPS pH 7, 50-200 mM AMMONIUM SULFATE, 50 mM MnCl2, AND 6-9% PEG-3350 , VAPOR DIFFUSION, HANGING DROP, temperature 295K
Unit Cell:
a: 78.170 Å b: 153.250 Å c: 52.720 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.28 Solvent Content: 46.01
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.6800 29.0530 69982 2799 95.8000 0.1649 0.1918 21.9192
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.680 30.0 95.800 0.067 ? 17.480 5.9 73143 70045 ? -3.000 25.996
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.680 1.720 90.300 ? ? 2.230 4.8 5325
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MAX II BEAMLINE I911-2 1.03796 MAX II I911-2
Software
Software Name Purpose Version
XSCALE data scaling .
PHASER phasing 2.1.4
PHENIX refinement 1.7.1_743
PDB_EXTRACT data extraction 3.10
MAR345 data collection .
XDS data reduction .